Ultrasonic Testing
System
OPCON-01 (LAM)
|
| |
|
|
| |
Ultrasonic system of testing contains following elements:
- UT-card (OPCON 01/100);
- Multiplexer with 16 channel (each contains
separate pulser&receiver)
- Alarm box (contains 2 relais) · Software package
|

|
| Technical
data |
|
A/D converter: |
|
- Resolution: |
8
bit |
|
- Sampling frequency: |
12.5,25,50
or 100MHz 1 |
| Analog
parameters: |
|
- Input amplifier gain: |
-10dB
- 50dB 1 |
|
- Input preamplifier |
0dB
or 10dB1 |
|
- Minimal sensitivity: |
0.1mV
- 1.6Vpp |
|
- Maximal sensitivity: |
50mV/Div
- 0.5Vpp |
| Bandwidth: |
0,1
- 25MHz |
| Input
impedance: |
50Ohm,
10pF |
| Trigger: |
internal
(software) |
| Delay
time: |
Post
trigger 256us, measurement accuracy better than 1ns |
| Data
buffer: |
256,
512, 1K, 2K,4K,8K,16K or 32K1 |
| |
1 - software selected |
| Characteristic
of the system |
The system is used mainly for testing of
parameter of plastic pipes during extrusion process (wall thickness,
diameter, ovality, eccentricity etc.) but can be used for any other
purpose, where such card or/and multiplexer are necessary.
|
|
Software Package: |
The software (only for Windows NT
4.0/2000/XP) includes all necessary functions for ultrasonic
measurements.
|
|